EDIFACT Standards to XML component
The EDIFACT Standards to XML component converts UN/EDIFACT messages into XML with less strict ruling. By converting EDIFACT messages into XML, these messages can be processed using other components available in Dovetail like the XLST component.
Supported standards
APERAC_D96B
DESADV_D93A
DESADV_D96A
IFCSUM_D08A
IFTFCC_D00B
IFTMBC_D98A
IFTMBC_D96B
IFTMBF_D08A
IFTMBF_D95B
IFTMIN_D96A
IFTMIN_D96A_UTF_8
IFTMIN_D98A
IFTMIN_D99A
IFTMIN_D99B
ORDERS_D93A
Differences with EDIFACT to XML component
This component works with transformations that are imported from custom mappings made in Altova Mapforce. They are supplied by a particular customer, but we make them available for everyone with their permission. In general these transformations are less strict and produce a different XML compared to the EDIFACT to XML component.
Example
Example for the IFTMIN D96A standard to XML transformation.
- Edifact Input
- XML Output
UNA:+.? '
UNB+UNOA:2+8714252014808::14+8714252011517::14+130402:1219+24535'
UNH+24546+IFTMIN:D:96A:UN'
BGM+340+347605+9'
DTM+137:20130402:102'
DTM+2:20130404:102'
DTM+200:20130403:102'
TSR+11++N'
FTX+DEL+++EXACT DONDERDAG 4.4 TUSSEN 8.15-12.00 UUR:AFLEVEREN'
TOD+6++CIP'
NAD+DP+++DUMMY B.V.+VERLENGDE VOORBEELDWEG 123+AMSTERDAM++1234AB+670'
NAD+CZ+++DUMMY WIRE & CABLE B.V.+INDUSTRIEGEBIED?: 1234:VOORBEELDWEG 10+AMSTERDAM++1234 AB+670'
CTA+IC+:JANE DOE'
COM+?+31(0)12 3456789:TE'
NAD+SF+++DUMMY WIRE & CABLE B.V.+INDUSTRIEGEBIED?: 1234:VOORBEELDWEG 10+AMSTERDAM++1234 AB+670'
CTA+IC+:JANE DOE'
COM+?+31(0)12 3456789:TE'
NAD+FW+++LOGISTICS B.V.++++1234 AB+670'
GID+1.0+1.0:E827::9'
HAN+UST::9'
MEA+AAE+G+KGM:24.0'
MEA+AAE+GMC+MTQ:80.0'
DIM+1+MTR:41.0:41.0:48.0'
PCI+33E'
GIN+BJ+00387142520086154710'
UNT+98126+24546'
UNZ+1+24535'
<?xml version="1.0"?>
<Envelope xmlns="http://www.blujaysolutions.com/2017/IFTMIN"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.blujaysolutions.com/2017/IFTMIN file:///C:/Users/jss/Documents/seacon/germany_interfaces/develop/iftmin_D96A/IFTMIN_D96A.xsd">
<Interchange>
<UNB>
<F0020>24535</F0020>
<S001>
<F0001>UNOA</F0001>
<F0002>2</F0002>
</S001>
<S002>
<F0004>8714252014808</F0004>
<F0008>14</F0008>
</S002>
<S003>
<F0010>8714252011517</F0010>
<F0014>14</F0014>
</S003>
<S004>
<F0017>130402</F0017>
<F0019>1219</F0019>
</S004>
</UNB>
<UNZ>
<F0036>1</F0036>
<F0020>24535</F0020>
</UNZ>
<Group>
<Message_IFTMIN>
<UNH>
<F0062>24546</F0062>
<S009>
<F0065>IFTMIN</F0065>
<F0052>D</F0052>
<F0054>96A</F0054>
<F0051>UN</F0051>
</S009>
</UNH>
<BGM>
<F1004>347605</F1004>
<F1225>9</F1225>
<C002>
<F1001>340</F1001>
</C002>
</BGM>
<DTM>
<C507>
<F2005>137</F2005>
<F2380>20130402</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<DTM>
<C507>
<F2005>2</F2005>
<F2380>20130404</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<DTM>
<C507>
<F2005>200</F2005>
<F2380>20130403</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<TSR>
<C536>
<F4065>11</F4065>
</C536>
<C537>
<F4219>N</F4219>
</C537>
</TSR>
<FTX>
<F4451>DEL</F4451>
<C108>
<F4440>EXACT DONDERDAG 4.4 TUSSEN 8.15-12.00 UUR</F4440>
<F4440>AFLEVEREN</F4440>
</C108>
</FTX>
<UNT>
<F0074>98126</F0074>
<F0062>24546</F0062>
</UNT>
<SG2>
<TOD>
<F4055>6</F4055>
<C100>
<F4053>CIP</F4053>
</C100>
</TOD>
</SG2>
<SG11>
<NAD>
<F3035>DP</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY B.V.</F3036>
</C080>
<C059>
<F3042>VERLENGDE VOORBEELDWEG 123</F3042>
</C059>
</NAD>
</SG11>
<SG11>
<NAD>
<F3035>CZ</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY WIRE & CABLE B.V.</F3036>
</C080>
<C059>
<F3042>INDUSTRIEGEBIED: 1234</F3042>
<F3042>VOORBEELDWEG 10</F3042>
</C059>
</NAD>
<SG12>
<CTA>
<F3139>IC</F3139>
<C056>
<F3412>JANE DOE</F3412>
</C056>
</CTA>
<COM>
<C076>
<F3148>+31(0)12 3456789</F3148>
<F3155>TE</F3155>
</C076>
</COM>
</SG12>
</SG11>
<SG11>
<NAD>
<F3035>SF</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY WIRE & CABLE B.V.</F3036>
</C080>
<C059>
<F3042>INDUSTRIEGEBIED: 1234</F3042>
<F3042>VOORBEELDWEG 10</F3042>
</C059>
</NAD>
<SG12>
<CTA>
<F3139>IC</F3139>
<C056>
<F3412>JANE DOE</F3412>
</C056>
</CTA>
<COM>
<C076>
<F3148>+31(0)12 3456789</F3148>
<F3155>TE</F3155>
</C076>
</COM>
</SG12>
</SG11>
<SG11>
<NAD>
<F3035>FW</F3035>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>LOGISTICS B.V.</F3036>
</C080>
</NAD>
</SG11>
<SG18>
<GID>
<F1496>1</F1496>
<C213>
<F7224>1</F7224>
<F7065>E827</F7065>
<F3055>9</F3055>
</C213>
</GID>
<HAN>
<C524>
<F4079>UST</F4079>
<F3055>9</F3055>
</C524>
</HAN>
<SG20>
<MEA>
<F6311>AAE</F6311>
<C502>
<F6313>G</F6313>
</C502>
<C174>
<F6411>KGM</F6411>
<F6314>24</F6314>
</C174>
</MEA>
</SG20>
<SG20>
<MEA>
<F6311>AAE</F6311>
<C502>
<F6313>GMC</F6313>
</C502>
<C174>
<F6411>MTQ</F6411>
<F6314>80</F6314>
</C174>
</MEA>
</SG20>
<SG21>
<DIM>
<F6145>1</F6145>
<C211>
<F6411>MTR</F6411>
<F6168>41</F6168>
<F6140>41</F6140>
<F6008>48</F6008>
</C211>
</DIM>
</SG21>
<SG23>
<PCI>
<F4233>33E</F4233>
</PCI>
<GIN>
<F7405>BJ</F7405>
<C208>
<F7402>00387142520086154710</F7402>
</C208>
</GIN>
</SG23>
</SG18>
</Message_IFTMIN>
</Group>
</Interchange>
</Envelope>