Skip to main content
Version: 4.17.3

XML to EDIFACT Standards component

The XML to EDIFACT Standards component allows you to convert XML messages produced by the EDIFACT Standards to XML component into UN/EDIFACT messages.

Use the EDIFACT Standards to XML component to convert EDIFACT messages into XML, allowing further processing, for example, using the XSLT component. After processing, the XML can be converted back into UN/EDIFACT using this component.

Configuration

The XML to CSV component has the following configuration options:

UN/EDIFACT type

Specify the UN/EDIFACT standard for the output data.

Options

  • XML to IFTFCC_D00B (default)
  • XML to IFTMBF_D95B
  • XML to INVOIC_D96A
  • XML to IFTMIN_D99B
custom mappings

This component works with transformations that are imported from custom mappings made in Altova Mapforce. They are supplied by a particular customer, but we make them available for everyone with their permission. These transformations work with the EDIFACT XML generated by the EDIFACT Standards to XML component

Using XML to EDIFACT Standards component

See an example below for the XML to IFTCC D00B standard.

<?xml version="1.0" encoding="UTF-8"?>
<Envelope xmlns="http://www.blujaysolutions.com/2019/IFTFCC">
<Interchange>
<UNB>
<F0020>78905</F0020>
<S001>
<F0001>UNOC</F0001>
<F0002>3</F0002>
</S001>
<S002>
<F0004>315904425</F0004>
<F0007>1</F0007>
<F0008>315904425</F0008>
</S002>
<S003>
<F0010>878542765</F0010>
<F0007>01</F0007>
<F0014>315000554</F0014>
</S003>
<S004>
<F0017>191113</F0017>
<F0019>1220</F0019>
</S004>
</UNB>
<UNZ>
<F0036>1</F0036>
<F0020>78905</F0020>
</UNZ>
<Group>
<Message_IFTFCC>
<UNH>
<F0062>78905</F0062>
<S009>
<F0065>IFTFCC</F0065>
<F0052>D</F0052>
<F0054>00B</F0054>
<F0051>UN</F0051>
</S009>
</UNH>
<BGM>
<F1225>9</F1225>
<C002>
<F1001>780</F1001>
</C002>
<C106>
<F1004>792281</F1004>
</C106>
</BGM>
<DTM>
<C507>
<F2005>3</F2005>
<F2380>20191111</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<DOC>
<C002>
<F1001>190</F1001>
<F1000>VAT-Export-Certificate</F1000>
</C002>
</DOC>
<UNT>
<F0074>38</F0074>
<F0062>78905</F0062>
</UNT>
<SG1>
<LOC>
<F3227>47</F3227>
<C517>
<F3225>NON EU</F3225>
</C517>
</LOC>
</SG1>
<SG3>
<MOA>
<C516>
<F5025>339</F5025>
<F5004>530</F5004>
<F6345>EUR</F6345>
<F6343>4</F6343>
</C516>
</MOA>
</SG3>
<SG4>
<TAX>
<F5283>7</F5283>
<F5305>G</F5305>
<C241>
<F5153>VAT</F5153>
</C241>
<C243>
<F5278>0</F5278>
<F5273>1</F5273>
</C243>
</TAX>
<MOA>
<C516>
<F5025>1</F5025>
<F5004>0</F5004>
<F6345>EUR</F6345>
</C516>
</MOA>
</SG4>
<SG5>
<CUX>
<C504>
<F6347>5</F6347>
<F6345>EUR</F6345>
<F6343>4</F6343>
</C504>
</CUX>
</SG5>
<SG11>
<NAD>
<F3035>CZ</F3035>
<F3164>Ludwigshafen Friesenheim/Nord</F3164>
<F3251>67063</F3251>
<F3207>DE</F3207>
<C080>
<F3036>BASF SE</F3036>
</C080>
<C059>
<F3042>Carl-Bosch-Str. 38</F3042>
</C059>
</NAD>
<SG13>
<RFF>
<C506>
<F1153>AHI</F1153>
<F1154>2009644133 IMO</F1154>
</C506>
</RFF>
</SG13>
</SG11>
<SG11>
<NAD>
<F3035>IV</F3035>
<F3164>Ludwigshafen</F3164>
<F3251>67074</F3251>
<F3207>DE</F3207>
<C082>
<F3039>1000</F3039>
</C082>
<C080>
<F3036>BASF SE</F3036>
<F3036>Accounting</F3036>
</C080>
</NAD>
<SG13>
<RFF>
<C506>
<F1153>VA</F1153>
<F1154>DE149145247</F1154>
</C506>
</RFF>
</SG13>
</SG11>
<SG11>
<NAD>
<F3035>II</F3035>
<F3164>Neuss</F3164>
<F3251>41468</F3251>
<F3207>DE</F3207>
<C082>
<F3039>463053</F3039>
</C082>
<C080>
<F3036>ICT Internationale</F3036>
<F3036>Container Transport GmbH</F3036>
</C080>
<C059>
<F3042>Sperberweg 6a</F3042>
</C059>
</NAD>
<SG13>
<RFF>
<C506>
<F1153>VA</F1153>
<F1154>DE120680511</F1154>
</C506>
</RFF>
</SG13>
</SG11>
<SG11>
<NAD>
<F3035>CA</F3035>
<F3164>Neuss</F3164>
<F3251>41468</F3251>
<F3207>DE</F3207>
<C082>
<F3039>463053</F3039>
</C082>
<C080>
<F3036>ICT Internationale</F3036>
<F3036>Container Transport GmbH</F3036>
</C080>
<C059>
<F3042>Sperberweg 6a</F3042>
</C059>
</NAD>
<SG13>
<RFF>
<C506>
<F1153>AAS</F1153>
<F1154>911/USKC/74426</F1154>
</C506>
</RFF>
</SG13>
</SG11>
<SG17>
<TDT>
<F8051>1</F8051>
<C220>
<F8067>3</F8067>
</C220>
<C228>
<F8179>31</F8179>
</C228>
</TDT>
<DTM>
<C507>
<F2005>11</F2005>
<F2380>20191111</F2380>
<F2379>102</F2379>
</C507>
</DTM>
</SG17>
<SG28>
<CNI>
<F1490>1</F1490>
</CNI>
<TCC>
<C200>
<F8023>101021</F8023>
<F8022>Gesamtfracht</F8022>
</C200>
<C203>
<F5243>N</F5243>
<F5242>ZEVL</F5242>
</C203>
</TCC>
<FTX>
<F4451>AAA</F4451>
<F4453>1</F4453>
<C108>
<F4440>Agnique® BL 3648</F4440>
</C108>
</FTX>
<FTX>
<F4451>INV</F4451>
<C108>
<F4440>Vorlaufkosten TRUCK</F4440>
</C108>
</FTX>
<MOA>
<C516>
<F5025>128</F5025>
<F5004>480</F5004>
<F6345>EUR</F6345>
<F6343>4</F6343>
</C516>
</MOA>
<SG30>
<LOC>
<F3227>5</F3227>
<C517>
<F3225>DEDUS</F3225>
<F3055>6</F3055>
<F3224>Düsseldorf</F3224>
</C517>
</LOC>
</SG30>
<SG30>
<LOC>
<F3227>7</F3227>
<C517>
<F3225>NLRTM</F3225>
<F3055>6</F3055>
<F3224>ROTTERDAM</F3224>
</C517>
</LOC>
</SG30>
<SG31>
<RFF>
<C506>
<F1153>LI</F1153>
<F1154>3534734934</F1154>
</C506>
</RFF>
</SG31>
<SG37>
<GID>
<F1496>1</F1496>
<C213>
<F7224>20</F7224>
<F7065>IBC</F7065>
</C213>
</GID>
<SG38>
<MEA>
<F6311>WT</F6311>
<C502>
<F6313>AAD</F6313>
</C502>
<C174>
<F6411>KGM</F6411>
<F6314>18870</F6314>
</C174>
</MEA>
</SG38>
<SG38>
<MEA>
<F6311>WT</F6311>
<C502>
<F6313>AAE</F6313>
</C502>
<C174>
<F6411>KGM</F6411>
<F6314>17700</F6314>
</C174>
</MEA>
</SG38>
</SG37>
</SG28>
<SG28>
<CNI>
<F1490>2</F1490>
</CNI>
<TCC>
<C200>
<F8023>101021</F8023>
<F8022>Gesamtfracht</F8022>
</C200>
<C203>
<F5243>N</F5243>
<F5242>ZEVL</F5242>
</C203>
</TCC>
<FTX>
<F4451>INV</F4451>
<C108>
<F4440>Vorlauf/Zusatzkosten: Terminalzuschlag ECT Delta</F4440>
</C108>
</FTX>
<MOA>
<C516>
<F5025>128</F5025>
<F5004>50</F5004>
<F6345>EUR</F6345>
<F6343>4</F6343>
</C516>
</MOA>
<SG30>
<LOC>
<F3227>5</F3227>
<C517>
<F3225>DEDUS</F3225>
<F3055>6</F3055>
<F3224>Düsseldorf</F3224>
</C517>
</LOC>
</SG30>
<SG30>
<LOC>
<F3227>7</F3227>
<C517>
<F3225>NLRTM</F3225>
<F3055>6</F3055>
<F3224>ROTTERDAM</F3224>
</C517>
</LOC>
</SG30>
<SG31>
<RFF>
<C506>
<F1153>LI</F1153>
<F1154>3534734934</F1154>
</C506>
</RFF>
</SG31>
</SG28>
</Message_IFTFCC>
</Group>
</Interchange>
</Envelope>
Last update on Feb 25, 2025